Senseca
PTI Resistance Thermometer
Resistance thermometer with a replaceable measuring insert for process temperature measurement.
Pt100 or Pt1000 sensing elements
Standard temperature range of −70…+300 °C, with +500 °C or +600 °C versions available on request
Tolerance classes AA, A and B according to IEC 60751
Seamless 1.4571 stainless steel protection tube
Optional head transmitter with 4…20 mA or 0…10 V output
Selectable process connections, connection heads and wiring configurations
Overview
The Senseca PTI is a resistance thermometer with a replaceable measuring insert designed for process temperature measurement using Pt100 or Pt1000 platinum resistance elements. It covers a standard measuring range of −70 to +300 °C at the probe tip, with high-temperature versions of +500 °C or +600 °C available on request. The measuring element is embedded in magnesium oxide powder to support effective heat transfer and vibration protection.
The thermometer features a seamless 1.4571 (AISI 316Ti) stainless steel protection tube and offers tolerance classes AA, A and B according to IEC 60751. It supports multiple wiring configurations, selectable process connections, connection heads and sensor lengths. Optional head transmitters provide 4…20 mA or 0…10 V output, with software-programmable and PROFIBUS PA versions also available.
Typical Applications
Process temperature measurement using immersion sleeves
High-temperature monitoring using optional high-temperature versions
Heat quantity measurement using paired Class AA sensors
Temperature monitoring at measuring points requiring vibration protection
Analogue temperature signal integration into control and monitoring systems using optional head transmitters
Key Features
Pt100 or Pt1000 platinum resistance measuring elements
Standard measuring range of −70…+300 °C at the probe tip, with +500 °C or +600 °C versions available on request
Tolerance classes AA, A and B according to IEC 60751
Magnesium oxide powder filling for effective heat transfer and vibration protection
Replaceable measuring insert
Seamless 1.4571 (AISI 316Ti) stainless steel protection tube
Single, double and triple Pt100 configurations with selectable wiring arrangements
Optional head transmitters with 4…20 mA or 0…10 V output, software-programmable or PROFIBUS PA versions
Selectable process connections and connection head materials
Preferred sensor lengths of 50, 100 and 150 mm
Optional neck tube with a preferred length of 100 mm
Benefits
Accurate and reproducible temperature measurements with selectable accuracy levels
Effective heat transfer and vibration protection for reliable sensing
Wide temperature coverage to accommodate different process conditions
Easier maintenance through a replaceable measuring insert
Flexible installation through selectable process connections, connection heads and sensor lengths
Convenient integration into control and monitoring systems through optional head transmitters
Specifications
Measurement | |
|---|---|
Measuring principle | Platinum resistance measurement |
Measuring element | Pt100 or Pt1000; others on request |
Standard measuring range | −70…+300 °C at the measuring tip |
High-temperature versions | +500 °C or +600 °C on request |
Low-temperature versions | Available on request |
Tolerance classes | AA, A and B according to IEC 60751, up to +300 °C; Class B preferred |
Paired sensor version | Class AA for heat quantity measurement |
Measuring element filling | Magnesium oxide powder |
Measuring insert | Replaceable |
Sensor Configuration and Wiring | |
|---|---|
Single Pt100 | 1 × Pt100, 2-, 3- or 4-wire; 3-wire preferred |
Double Pt100 | 2 × Pt100, 2 × 2-wire or 2 × 3-wire |
Triple Pt100 | 3 × Pt100, 3 × 2-wire |
Single Pt1000 | 1 × Pt1000, 3-wire |
Measuring insert diameter requirement | Minimum Ø 8 mm for double and triple Pt100 configurations with replaceable measuring inserts |
Signal Output and Transmitter | |
|---|---|
Fixed-value head transmitter output | 4…20 mA or 0…10 V |
Software-programmable head transmitter | UTN-500 |
Digital interface | PROFIBUS PA via PTN-600 head transmitter |
Head transmitter mounting requirement | Large connection head |
Electrical Connection | |
|---|---|
Terminal connection | Single or double terminal socket; single terminal socket preferred |
Flying leads | Wire ends for head transmitter installation |
Plug connection | 5-pole M12 plug |
Dual head transmitter connection | Available |
Special connection versions | Available on request |
Process Connection | |
|---|---|
Threaded process connection | G½″ or G1″ male thread; G½″ preferred |
Compatible immersion capsules for G½″ connection | STHA, STHB and STHX |
Other process connections | Available on request |
Pressure-tight installation | Only with an appropriately matched immersion capsule |
Process-Side Materials | |
|---|---|
Protection tube | Seamless stainless steel 1.4571 (AISI 316Ti) |
Flanges and process connections | Stainless steel 1.4571 (AISI 316Ti) |
Special materials | Available on request |
Connection Head | |
|---|---|
Small connection head | Polypropylene (PP) |
Large plastic connection head | Delrin® (preferred) |
Large aluminium connection head | Available |
Large steel connection head | Available |
Double-sized aluminium connection head | Available |
Other connection head versions | Available on request |
Dimensions and Installation | |
|---|---|
Preferred measuring insert diameter | Ø 5 mm |
Corresponding STH immersion sleeve inner diameter | Ø 6 mm |
Preferred sensor length (L1) | 50, 100 or 150 mm |
Recommended minimum immersion depth | 50 mm |
Neck tube configuration | With or without neck tube |
Neck tube length (L2) | Preferred length of 100 mm; other lengths on request |
Regulatory Compliance | |
|---|---|
RoHS Directive | 2011/65/EU |
General Product Safety Regulation (GPSR) | Regulation (EU) 2023/988 |
EMC Directive | 2014/30/EU |
Restriction of hazardous substances standard | EN 63000:2019 |
Electrical measuring equipment safety standard | EN 61010-1:2023 |
General EMC requirements | EN 61326-1:2022 |
Particular EMC requirements | EN 61326-2-3:2022 |
ATEX Compliance – Ex-Marked Versions Only | |
|---|---|
ATEX Directive | 2014/34/EU |
ATEX markings listed in the declaration | II 1G, II 1/2G, II 2G, II 1D, II 1/2D, II 2D |
Applicable standards | EN 60079-0:2025, EN 60079-11:2012, EN 60079-26:2024 |
EU Type Examination Certificate | TÜV 04 ATEX 2430 X-01 |
EU Type Examination body | TÜV Nord Cert (RN0044) |
Quality assurance body | DEKRA Testing and Certification GmbH (RN0158) |
Drawing

Downloads
| PTI Family Datasheet | DownloadPTI Family Datasheet |
|---|---|
| PTI CE Declaration of Conformity | DownloadPTI CE Declaration of Conformity |
Related Products
Senseca
UNICON-LF-01/02/03 Conductivity Converter
Conductivity converter for liquid purity and concentration monitoring.
Learn More
Senseca
LF4003 Conductivity Cell for Wells and Open Water Systems
4-electrode immersion conductivity cell for wells and open systems up to 100 m depth.
Learn More
Senseca
ORP211 Combined Redox Electrode for Polluted Wastewater Media
Combined Redox electrode for heavily polluted media in wastewater and process chemistry.
Learn MoreSenseca
UNICON-PH-01/02 pH and ORP Converter
pH and ORP converter for process monitoring with programmable ranges of −1.00 to +15.00 pH or ±1500 mV, Pt100/Pt1000 temperature compensation, 4–20 mA output…
Learn More