Resistance thermometer with a replaceable measuring insert for process temperature measurement.

  • Pt100 or Pt1000 sensing elements

  • Standard temperature range of −70…+300 °C, with +500 °C or +600 °C versions available on request

  • Tolerance classes AA, A and B according to IEC 60751

  • Seamless 1.4571 stainless steel protection tube

  • Optional head transmitter with 4…20 mA or 0…10 V output

  • Selectable process connections, connection heads and wiring configurations

Quantity
1

Overview

The Senseca PTI is a resistance thermometer with a replaceable measuring insert designed for process temperature measurement using Pt100 or Pt1000 platinum resistance elements. It covers a standard measuring range of −70 to +300 °C at the probe tip, with high-temperature versions of +500 °C or +600 °C available on request. The measuring element is embedded in magnesium oxide powder to support effective heat transfer and vibration protection.

The thermometer features a seamless 1.4571 (AISI 316Ti) stainless steel protection tube and offers tolerance classes AA, A and B according to IEC 60751. It supports multiple wiring configurations, selectable process connections, connection heads and sensor lengths. Optional head transmitters provide 4…20 mA or 0…10 V output, with software-programmable and PROFIBUS PA versions also available.

Typical Applications

  • Process temperature measurement using immersion sleeves

  • High-temperature monitoring using optional high-temperature versions

  • Heat quantity measurement using paired Class AA sensors

  • Temperature monitoring at measuring points requiring vibration protection

  • Analogue temperature signal integration into control and monitoring systems using optional head transmitters

Key Features

  • Pt100 or Pt1000 platinum resistance measuring elements

  • Standard measuring range of −70…+300 °C at the probe tip, with +500 °C or +600 °C versions available on request

  • Tolerance classes AA, A and B according to IEC 60751

  • Magnesium oxide powder filling for effective heat transfer and vibration protection

  • Replaceable measuring insert

  • Seamless 1.4571 (AISI 316Ti) stainless steel protection tube

  • Single, double and triple Pt100 configurations with selectable wiring arrangements

  • Optional head transmitters with 4…20 mA or 0…10 V output, software-programmable or PROFIBUS PA versions

  • Selectable process connections and connection head materials

  • Preferred sensor lengths of 50, 100 and 150 mm

  • Optional neck tube with a preferred length of 100 mm

Benefits

  • Accurate and reproducible temperature measurements with selectable accuracy levels

  • Effective heat transfer and vibration protection for reliable sensing

  • Wide temperature coverage to accommodate different process conditions

  • Easier maintenance through a replaceable measuring insert

  • Flexible installation through selectable process connections, connection heads and sensor lengths

  • Convenient integration into control and monitoring systems through optional head transmitters

Specifications

Measurement

Measuring principle

Platinum resistance measurement

Measuring element

Pt100 or Pt1000; others on request

Standard measuring range

−70…+300 °C at the measuring tip

High-temperature versions

+500 °C or +600 °C on request

Low-temperature versions

Available on request

Tolerance classes

AA, A and B according to IEC 60751, up to +300 °C; Class B preferred

Paired sensor version

Class AA for heat quantity measurement

Measuring element filling

Magnesium oxide powder

Measuring insert

Replaceable

 

 

Sensor Configuration and Wiring

Single Pt100

1 × Pt100, 2-, 3- or 4-wire; 3-wire preferred

Double Pt100

2 × Pt100, 2 × 2-wire or 2 × 3-wire

Triple Pt100

3 × Pt100, 3 × 2-wire

Single Pt1000

1 × Pt1000, 3-wire

Measuring insert diameter requirement

Minimum Ø 8 mm for double and triple Pt100 configurations with replaceable measuring inserts

 

 

Signal Output and Transmitter

Fixed-value head transmitter output

4…20 mA or 0…10 V

Software-programmable head transmitter

UTN-500

Digital interface

PROFIBUS PA via PTN-600 head transmitter

Head transmitter mounting requirement

Large connection head

 

 

Electrical Connection

Terminal connection

Single or double terminal socket; single terminal socket preferred

Flying leads

Wire ends for head transmitter installation

Plug connection

5-pole M12 plug

Dual head transmitter connection

Available

Special connection versions

Available on request

 

 

Process Connection

Threaded process connection

G½″ or G1″ male thread; G½″ preferred

Compatible immersion capsules for G½″ connection

STHA, STHB and STHX

Other process connections

Available on request

Pressure-tight installation

Only with an appropriately matched immersion capsule

 

 

Process-Side Materials

Protection tube

Seamless stainless steel 1.4571 (AISI 316Ti)

Flanges and process connections

Stainless steel 1.4571 (AISI 316Ti)

Special materials

Available on request

 

 

Connection Head

Small connection head

Polypropylene (PP)

Large plastic connection head

Delrin® (preferred)

Large aluminium connection head

Available

Large steel connection head

Available

Double-sized aluminium connection head

Available

Other connection head versions

Available on request

 

 

Dimensions and Installation

Preferred measuring insert diameter

Ø 5 mm

Corresponding STH immersion sleeve inner diameter

Ø 6 mm

Preferred sensor length (L1)

50, 100 or 150 mm

Recommended minimum immersion depth

50 mm

Neck tube configuration

With or without neck tube

Neck tube length (L2)

Preferred length of 100 mm; other lengths on request

 

 

Regulatory Compliance

RoHS Directive

2011/65/EU

General Product Safety Regulation (GPSR)

Regulation (EU) 2023/988

EMC Directive

2014/30/EU

Restriction of hazardous substances standard

EN 63000:2019

Electrical measuring equipment safety standard

EN 61010-1:2023

General EMC requirements

EN 61326-1:2022

Particular EMC requirements

EN 61326-2-3:2022

 

 

ATEX Compliance – Ex-Marked Versions Only

ATEX Directive

2014/34/EU

ATEX markings listed in the declaration

II 1G, II 1/2G, II 2G, II 1D, II 1/2D, II 2D

Applicable standards

EN 60079-0:2025, EN 60079-11:2012, EN 60079-26:2024

EU Type Examination Certificate

TÜV 04 ATEX 2430 X-01

EU Type Examination body

TÜV Nord Cert (RN0044)

Quality assurance body

DEKRA Testing and Certification GmbH (RN0158)

Drawing

PTI Resistance Thermometer Drawing

Downloads