WETEC

ECD

S80 Conductivity Sensors


Intelligent digital contacting conductivity sensor for real-time process monitoring.

  • Wide conductivity measurement range with a response time of less than 5 seconds

  • Two-way digital communication with onboard sensor identification and calibration data storage

  • Insertion, submersion or valve-retractable configurations

  • Standard wetted materials: 316 stainless steel, PEEK and Viton

Quantity
1

Overview

The ECD S80 Conductivity Sensor is an intelligent digital sensor designed for real-time process monitoring. It measures conductivity by determining the electrical impedance between two metal electrodes in a solution. Its standard wetted materials include 316 stainless steel, PEEK insulators and Viton O-rings.

The sensor supports two-way digital communication with compatible ECD transmitters and controllers. Its internal memory stores the sensor identity, measurement type, serial number and calibration data, enabling automatic configuration of the transmitter's display and outputs upon connection. The S80 is available in insertion/submersion and valve-retractable designs, with adjustable insertion lengths and various process connection options to accommodate different installation requirements.

Typical Applications

  • Conductivity measurement in liquid process streams

  • In-line monitoring in pipelines and flow cells

  • Submerged conductivity measurement in process tanks

  • Continuous monitoring in processes requiring sensor maintenance without interrupting sample flow (valve-retractable configuration)

Key Features

  • Contacting conductivity measurement using two metal electrodes

  • Wide conductivity measurement range

  • Measurement response time of less than 5 seconds

  • Two-way digital communication with compatible ECD transmitters and controllers

  • Internal storage of sensor identity, measurement type, serial number and calibration data

  • Factory calibrated for plug-and-play installation

  • Insertion/submersion and valve-retractable configurations with adjustable insertion lengths

  • Standard wetted materials: 316 stainless steel, PEEK insulators and Viton O-rings

  • Standard 10 ft cable with optional cable lengths and detachable cable connection

  • Standard ¾-inch diameter housing with 10-inch insertion or 17-inch valve-retractable sensor length

  • Various housing materials and process connection options

Benefits

  • Wide measurement range accommodates various conductivity monitoring applications

  • Factory calibration and onboard calibration data storage simplify field installation

  • Automatic sensor recognition reduces manual transmitter configuration

  • Flexible mounting configurations accommodate different process installation requirements

  • Valve-retractable design enables sensor maintenance without shutting down the process line

  • Various housing material options allow compatibility with different process liquids

  • Optional detachable cable connection simplifies sensor replacement

Specifications

Conductivity Measurement

Measuring principle

Electrical impedance between two metal contacts in solution

Measurement range

0.5 μS…50 mS¹

Accuracy

±0.2 FS

Resolution

0.01

Response time

<5 s

 

 

Temperature Measurement

Temperature range

−5…+100 °C²

Temperature accuracy

±0.2

Temperature resolution

0.01

Temperature response time

<5 s

 

 

Electrode Design

Open-style electrode

Low conductivity measurements

Closed-style electrode

High conductivity measurements

 

 

Digital Communication and Calibration

Communication

Two-way digital communication

Compatible transmitter

ECD T80

Compatible controller

ECD LQ800

Internal memory

Sensor identity, sensor type, serial number and calibration registers

Sensor recognition

Automatic

Calibration

Factory calibrated; periodic calibration required

 

 

Mechanical

Sensor configurations

Insertion/submersion or valve retractable

Standard insertion sensor dimensions

¾″ OD × 10″ length

Standard valve-retractable sensor dimensions

¾″ OD × 17″ length

Insertion length

Adjustable

Valve-retractable design

Flanged blowout protector

Other housing lengths

Consult manufacturer

 

 

Materials of Construction

Standard housing material

316 stainless steel

Optional housing materials

Titanium, Hastelloy C-22 and polypropylene

Standard wetted metal material

316 stainless steel

Insulator material

PEEK

Standard O-ring material

Viton

Optional O-ring materials

Ethylene propylene, Viton 75, Kalrez and CV75

 

 

Process Connections

Insertion/submersion connection

¾″ MNPT compression fitting

Valve-retractable connection

1″ NPT valve retraction assembly

Threaded fitting options

¾″ MNPT or 1″ MNPT

Ferrule options

Nylon, Teflon or stainless steel

Sanitary flange options

1/1.5″, 2″ or 2½″

Additional flange option

150# flange

 

 

Cable and Connector

Standard cable length

10 ft

Optional cable lengths

20 ft, 30 ft, 40 ft, 50 ft or 100 ft

Other cable lengths

Consult manufacturer

Standard cable configuration

Integral cable

Optional connector

Straight (axial) detachable connector

Detachable connector protection

IP68

Downloads

S80 - Sensors Manual DownloadS80 - Sensors Manual