Senseca
TK4 Ultra-Compact Temperature Sensor
Ultra-compact temperature sensor with a fast-response platinum resistance sensing element for gases, vapours, liquids and dust.
Temperature measuring range −50…+200 °C
Pt100 or Pt1000 Class A sensing element
4…20 mA with FSK, RS485 Modbus-RTU or IO-Link output options
Fully welded measuring system with stainless steel construction
M12 electrical connection and IP69K/IP67 protection
Standard and hygienic process connection options
Overview
The THERMOCONT TK4SS is an ultra-compact temperature sensor designed for time-critical applications and restricted installation spaces. It measures temperatures in gases, vapours, liquids and dust within an overall range of −50 to +200 °C. Its thin-film platinum resistance sensing element is in direct contact with the probe tube, enabling efficient heat transfer, rapid response and accurate temperature measurement.
The sensor is available with Pt100 or Pt1000 Class A resistance outputs according to IEC 60751, as well as electronic output variants including 4…20 mA with FSK interface, RS485 Modbus-RTU and IO-Link. Its completely welded measuring system, stainless steel construction, M12 electrical connection and IP69K/IP67 protection support reliable industrial operation. Various threaded and hygienic process connections, together with an optional neck tube, provide flexibility for different installation requirements.
Typical Applications
Temperature measurement in gases, vapours, liquids and dust
Time-critical processes requiring rapid sensor response
Temperature measurement in restricted installation spaces
Elevated-temperature industrial processes
Hygienic process applications
Temperature regulation in industrial control systems
Key Features
Ultra-compact stainless steel sensor design
Maximum temperature measuring range −50…+200 °C
Thin-film Pt100 or Pt1000 Class A resistance sensor according to IEC 60751
Fast response times of t50 ≤ 1 s and t90 ≤ 2 s (water at 0.4 m/s, temperature step of 10 K)
4…20 mA with FSK interface, RS485 Modbus-RTU or IO-Link output variants
Completely welded measuring system sealed against the process
M12x1 A-coded electrical connection
IP69K/IP67 ingress protection
Threaded and hygienic process connection options
Optional neck tube for elevated process temperatures
Metallic sealing option for dead-space-free and elastomer-free process adaptation
Benefits
Rapid detection of temperature changes in time-critical processes
Easy installation in restricted spaces due to the ultra-compact design
Accurate temperature measurement through efficient heat transfer
Flexible integration into industrial control systems with a choice of output variants
Reliable process sealing through the completely welded measuring system
Robust operation in demanding industrial environments
Hygienic installation with optional dead-space-free and elastomer-free process adaptation
Reduced heat transfer to the electronics housing with an optional neck tube
Specifications
Temperature Measurement | |
|---|---|
Measuring principle | Platinum resistance measurement |
Sensing element | Thin-film platinum resistance sensor |
Measuring media | Gases, vapours, liquids and dust |
Maximum measuring range | −50…+200 °C |
Sensor standard | IEC 60751 |
Response time | t50 ≤ 1 s; t90 ≤ 2 s |
Response time test conditions | Water at 0.4 m/s, temperature step of 10 K, according to IEC 60751 |
Configurable Measuring Ranges | |
|---|---|
Measuring ranges starting at 0 °C | 0…+50 °C; 0…+100 °C; 0…+150 °C; 0…+200 °C |
Measuring ranges starting at −50 °C | −50…+50 °C; −50…+100 °C; −50…+150 °C; −50…+200 °C |
Measurement Performance | |
|---|---|
Pt100/Pt1000 measurement deviation | ±(0.15 K + 0.002 × |Tp|) or less |
Standard transmitter characteristic deviation [13-S] | ±(0.25 K + 0.002 × |Tp|) or less |
Xcellence characteristic deviation [13-X] | ≤ ±0.15 K |
Transmitter resolution | ≥ 16 bit (FSI) |
Transmitter long-term zero-point drift | ≤ ±0.1 K/year |
Measurement deviation standard | EN/IEC 60770-1 |
Transmitter start-up delay | ≤ 0.1 s (damping = 0 s) |
Pt100 and Pt1000 Resistance Outputs | |
|---|---|
Pt100 variant [09-C] | Pt100 Class A, 4-wire |
Pt1000 variant [09-D] | Pt1000 Class A, 4-wire |
Pt100 excitation current | 0.1…5 mA |
Pt1000 excitation current | 0.1…2 mA |
4…20 mA / FSK Output [09-A] | |
|---|---|
Wiring configuration | 2-wire |
Analogue output | 4…20 mA, corresponding to the configured measuring range |
Limit/error signal range | 3.9…20.5 mA |
Digital interface | FSK |
Communication rate | 1200 bit/s |
Communication resistance | ≥ 240 Ω, external |
RS485 Modbus-RTU Output [09-V] | |
|---|---|
Wiring configuration | 4-wire |
Communication interface | Bidirectional RS485 |
Communication protocol | Modbus-RTU |
Default baud rate | 9600 baud |
Input resistance | 112 kΩ |
IO-Link Output [09-L] | |
|---|---|
Wiring configuration | 4-wire |
Communication interface | IO-Link V1.1 |
Communication mode | COM2 |
Communication rate | 38400 baud |
Cycle time | ≥ 2.3 ms |
Analogue output options | 0…20 mA or 4…20 mA |
Limit signal range (4…20 mA) | 3.8…20.5 mA |
Limit signal range (0…20 mA) | 0…20.5 mA |
Permissible load resistance (RL) | ≤ (Us − 8 V) / 22 mA |
Switching Outputs (IO-Link Variant) | |
|---|---|
Switching output type | 2 × push-pull (PP) |
Switching direction | +L/−L |
Output voltage, low level | ≤ 0.2 V |
Output voltage, high level | ≥ Us − 2 V |
Output current | 0…200 mA |
Current limitation | ≤ 450 mA |
Short-circuit protection | Yes |
Switching delay | tᵣᵢₛₑ < 30 µs (RL < 3 kΩ, Io > 4.5 mA) |
Switching cycles | ≥ 100,000,000 |
Power Supply and Electrical Connection | |
|---|---|
Supply voltage – 4…20 mA/FSK | 9…35 VDC |
Supply voltage – RS485 | 6…35 VDC |
Supply voltage – IO-Link inactive | 9…35 VDC |
Supply voltage – IO-Link active | 18…30 VDC |
Input current – 4…20 mA/FSK | ≤ 20.5 mA |
Input current – RS485 | ≤ 10 mA, without load |
Input current – IO-Link | ≤ 20 mA, without load |
Reverse polarity protection | Yes, transmitter variants |
Residual ripple | ≤ 2 Vpp |
Analogue output current increment (dI) | ≤ 1 µA |
Supply voltage influence on analogue output | ≤ ±0.5 µA/V |
Ambient temperature influence on analogue output | ≤ ±0.5 µA/K |
Electrical connection | M12 × 1, A-coded plug |
Process Temperature | |
|---|---|
Pt100/Pt1000 variants | −50…+200 °C |
Transmitter variants without neck tube | −50…+150 °C |
Transmitter variants with neck tube | −50…+200 °C |
Front-flush O-ring connection with FKM/FPM seal | −15…+200 °C |
Front-flush O-ring connection with EPDM seal | −50…+140 °C |
Process Connections and Pressure | |
|---|---|
Without process connection | ≤ 100 bar (L1 ≤ 200 mm) |
G¼"A or G½"A, ISO 228-1 | ≤ 100 bar (L1 ≤ 200 mm) |
NPT ¼" or NPT ½", ANSI | ≤ 100 bar (L1 ≤ 200 mm) |
G½"A, front-flush O-ring | ≤ 40 bar |
G½"A, metallic sealing | ≤ 40 bar |
Milk pipe coupling, DIN 11851 – DN25 | ≤ 40 bar |
Clamp, DIN 32676 – DN25…40 / 1"…1½"; ISO 2852 – DN25…38 | ≤ 25 bar |
Varivent F – DN25…32 (1"…1¼"), Ø 50 mm | ≤ 25 bar, according to Section 7.6 |
Configuration | Ambient Temperature | Process Temperature |
|---|---|---|
Pt100/Pt1000 without neck tube | −40…+85 °C | −50…+200 °C |
Pt100/Pt1000 without neck tube | −40…+100 °C | −50…+150 °C |
Pt100/Pt1000 without neck tube | −40…+125 °C | −50…+125 °C |
Pt100/Pt1000 with neck tube | −40…+125 °C | −50…+200 °C |
Transmitter without neck tube | −40…+85 °C | −50…+150 °C |
Transmitter without neck tube | −40…+100 °C | −50…+125 °C |
Transmitter with neck tube | −40…+85 °C | −50…+200 °C |
Transmitter with neck tube | −40…+100 °C | −50…+150 °C |
Environmental Conditions | |
|---|---|
Storage and transport temperature | −20…+85 °C |
Storage and transport relative humidity | 20…85% RH |
Ingress protection | IP69K/IP67 (EN/IEC 60529) |
Climatic class | 4K4H (EN/IEC 60721-3-4) |
Shock resistance | 500 g (1 ms), EN/IEC 60068-2-27 |
Vibration resistance | 20 g (10…2000 Hz), EN/IEC 60068-2-6 |
Electromagnetic compatibility | Equipment Class B, industrial environment (EN/IEC 61326) |
Dielectric strength | 500 Vac |
Protection class | III |
Pollution degree | 4 |
Operating altitude | 2000 m above sea level |
Materials and Construction | |
|---|---|
Measuring system | Completely welded, sealed against the process |
Process-wetted metallic material | Stainless steel 1.4571/316Ti |
Process seal options | FKM/FPM – FDA; EPDM – FDA |
Process-side surface roughness | Ra ≤ 0.76 µm (ASME BPE – SF3) |
Non-process-wetted materials | CrNi steel, PUR, FKM/FPM |
Dimensions and Weight | |
|---|---|
Probe tube diameter | Ø 6 mm |
Standard probe tube lengths (L1) | 30, 50, 100, 150 and 200 mm |
Custom probe tube length (L1) | ≤ 300 mm |
Neck tube options | Without neck tube, 35 mm neck tube or custom length |
Custom neck tube length (L2) | 50…200 mm |
Weight | 0.1…1.0 kg |
Mean Time to Failure (MTTF) | |
|---|---|
Pt100 [09-C] | 13,091 years |
Pt1000 [09-D] | 13,091 years |
4…20 mA/FSK [09-A] | 745 years |
RS485 Modbus-RTU [09-V] | 561 years |
IO-Link [09-L] | 601 years |
Additional Options | |
|---|---|
Special version | LABS-free, silicone-free, paint-compatible |
Measuring point identification | TAG laser marking |
Material inspection certificate | EN 10204 3.1 |
Factory certificate | Drinking water suitability |
Configuration | Factory configuration/presetting |
Standards and Compliance | |
|---|---|
RoHS Directive | 2011/65/EU |
General Product Safety Regulation (GPSR) | EU 2023/988 |
EMC Directive | 2014/30/EU |
Restriction of hazardous substances | EN 63000:2019 |
Electrical measuring instrument safety | EN 61010-1:2023 |
EMC requirements for measuring instruments | EN 61326-1:2022 |
Particular EMC requirements | EN 61326-2-3:2022 |
Downloads
| TK4 Family Datasheet | DownloadTK4 Family Datasheet |
|---|---|
| TK4 User Manual | DownloadTK4 User Manual |
| TK4 CE Declaration of Conformity | DownloadTK4 CE Declaration of Conformity |
Related Products
Senseca
UNICON-LF-01/02/03 Conductivity Converter
Conductivity converter for liquid purity and concentration monitoring.
Learn More
Senseca
LF4003 Conductivity Cell for Wells and Open Water Systems
4-electrode immersion conductivity cell for wells and open systems up to 100 m depth.
Learn More
Senseca
ORP211 Combined Redox Electrode for Polluted Wastewater Media
Combined Redox electrode for heavily polluted media in wastewater and process chemistry.
Learn MoreSenseca
UNICON-PH-01/02 pH and ORP Converter
pH and ORP converter for process monitoring with programmable ranges of −1.00 to +15.00 pH or ±1500 mV, Pt100/Pt1000 temperature compensation, 4–20 mA output…
Learn More