Triton DO90 ppb Dissolved Oxygen Analyzer

WaterWater Quality Measurement

Trace dissolved oxygen analyzer for continuous monitoring in aqueous systems, particularly boiler feedwater.

  • Measuring range: 0.001…20.00 mg/L with ppm/ppb auto-ranging

  • Lead-silver galvanic measuring principle

  • Process temperature range: −5…+50 °C

  • Replaceable electrode cartridge

  • Digital signal output

Quantity
1

Overview

The Triton® DO90 is an analyzer designed for continuous measurement of trace dissolved oxygen levels in aqueous systems, particularly boiler feedwater. It uses a lead-silver galvanic sensor with a durable PFA Teflon® membrane, covering a measuring range of 0.001…20.00 mg/L with ppm/ppb auto-ranging and a process temperature range of −5…+50 °C.

The sensor incorporates internal signal conditioning, calibration and diagnostic functions, providing a digital signal to the Model T80 Transmitter. Its replaceable electrode cartridge simplifies maintenance by eliminating the need for electrolyte and membrane replacement kits. The analyzer is available as separate components, a complete panel-mounted system or a kit for installation on an existing water panel.

Typical Applications

  • Trace dissolved oxygen measurement in aqueous systems

  • Boiler feedwater monitoring

  • Steam cycle monitoring to support corrosion prevention

Key Features

  • Lead-silver galvanic sensor with a PFA Teflon® membrane

  • Measuring range of 0.001…20.00 mg/L with ppm/ppb auto-ranging

  • Process temperature range of −5…+50 °C

  • Replaceable electrode cartridge

  • Digital signal transmission via a shielded 4-wire cable

  • 100 kΩ NTC temperature sensor with compensation from 0…50 °C

  • Internal signal conditioning and diagnostic functions

  • Air and zero calibration

  • AISI 316 Ti stainless steel sensor body

  • Response time of t90: 30 seconds and t99: 90 seconds

  • Compatible with the Model T80 Transmitter

  • Available as separate components, a complete panel-mounted system or a kit without the panel

Benefits

  • Wide measurement coverage for trace and higher dissolved oxygen concentrations

  • Long-term measurement stability with minimal drift

  • Continuous in-process monitoring eliminates grab sampling errors

  • Simplified maintenance without the need for electrolyte or membrane replacement kits

  • Easy calibration using air and zero calibration methods

  • Noise-free digital signal transmission

  • Flexible installation to accommodate new or existing water panels

Specifications

Measurement

Measured parameter

Dissolved oxygen

Measuring principle

Galvanic, silver cathode, lead anode, self-polarizing

Measurement signal

Current signal proportional to oxygen partial pressure

Measuring range

0.001…20.00 mg/L or ppm/ppb auto-ranging

Slope

Approximately 1.5 nA/ppb O₂ at 20 °C and 1013 hPa

Response time

t90: 30 s; t99: 90 s

Polarization time

<60 minutes

Drift

<1% per month under continuous polarization

 

 

Process Operating Conditions

Process temperature range

−5…+50 °C

Process pressure range

0…15 psi maximum overpressure

Vacuum operation

Not permitted

Minimum flow rate

200 mL/min with flow cell (P/N 1000008-1)

 

 

Temperature Compensation

Temperature sensor

NTC, 100 kΩ

Temperature compensation range

0…50 °C

 

 

Calibration

Calibration methods

Air calibration and zero calibration

Calibration storage

Stored in the sensor

 

 

Electrical Connection and Signal

Signal output

Digital signal

Electrical connection

Shielded 4-wire cable

Maximum total cable length

100 m cable extension

Compatible transmitter

Model T80 Transmitter

 

 

Materials of Construction

Sensor body

Flanged AISI 316 Ti stainless steel

Electrode body

PEEK

Membrane

PFA Teflon®

Cathode

Silver

Anode

Lead

Membrane thickness

Approximately 2 mil

Flow cell wetted parts

316L stainless steel

 

 

Process Connection

Tube fittings

¼″ 316 stainless steel

Flow cell mounting

Wall mounting using clamp-style holders or panel mounting using two 10 × 32 threaded ports

 

 

System Configuration

Available configurations

Separate components, complete panel-mounted system or kit without panel

Panel dimensions

17″ × 12″

Power supply options (panel-mounted system)

Loop powered or 110/220 VAC

 

 

Shipping Weight

Model DO90 sensor with 10 ft cable

0.7 kg

Stainless steel flow cell

2.0 kg

Drawing

Triton DO90 ppb Dissolved Oxygen Analyzer Drawing