WETEC

ECD

Triton TR80 Turbidity / Suspended Solids Sensor

WaterWater Quality Measurement

Digital turbidity and suspended solids sensor for water and wastewater monitoring.

  • 90° near-infrared light scattering method

  • Turbidity measurement up to 4000 NTU, depending on sensor configuration

  • Automated cleaning wiper with programmable frequency and duration

  • Immersion, flow-through and valve retractable installation options

  • Compatible with T80 Transmitter and LQ800 Multi-Channel Controller

Quantity
1

Overview

The Triton TR80 is a digital nephelometric sensor designed to measure turbidity and suspended solids in water and wastewater. It uses a near-infrared LED light source and a 90° light scattering method, providing high sensitivity throughout its measurement range. An automated mechanical cleaning wiper with programmable frequency and duration helps maintain a clean optical surface.

The TR80 supports multiple measurement ranges and incorporates internal temperature compensation. It offers immersion, flow-through and valve retractable installation options to accommodate different application requirements. The sensor is compatible with the ECD T80 Transmitter and LQ800 Multi-Channel Controller.

Typical Applications

  • Turbidity monitoring in environmental water

  • Suspended solids measurement in wastewater

  • Continuous online monitoring in industrial aqueous processes

  • Low-turbidity measurement in flow-through systems

Key Features

  • Nephelometric measurement of turbidity and suspended solids using a near-infrared LED and 90° light scattering

  • Turbidity measurement up to 4000 NTU, depending on sensor configuration

  • Automated mechanical cleaning wiper with programmable frequency and duration

  • Internal temperature compensation

  • Digital communication with T80 Transmitter and LQ800 Multi-Channel Controller

  • Immersion, flow-through and valve retractable installation options

  • CPVC sensor body with optional polypropylene construction

  • Waterproof six-wire measuring cable available in 3.0, 6.1 or 9.1 m lengths

  • Factory-calibrated sensor with three-point calibration capability

Benefits

  • High sensitivity throughout the selected turbidity measurement range

  • Reduced manual cleaning requirements through automated optical surface cleaning

  • Flexible installation to accommodate different process configurations

  • Integration with compatible ECD transmitters and controllers

  • Simplified initial setup through factory calibration

  • Compensation for temperature variations during measurement

Specifications

Measurement

Measured parameters

Turbidity and suspended solids

Measuring principle

Nephelometric optical measurement

Light source

Near-infrared LED

Detection method

90° light scattering

Measurement units

NTU, FNU, ppm, mg/L and % solids

Temperature compensation

Internal temperature compensation

 

 

Turbidity Measuring Ranges code

0

0…1000 NTU

2

0…4000 NTU

4

Below 40 NTU (calibration in flow cell or de-bubbler assembly)

 

 

Operating Conditions

Process pH range

2…12

Maximum process pressure

50 psi (in flow cell)

Application medium

Aqueous solutions

 

 

Cleaning System

Cleaning mechanism

Automated mechanical wiper

Cleaning frequency and duration

Programmable

Manual activation

Remote switch

 

 

Mechanical

Sensor length

10 inches

Sensor diameter

1.315 inches

Sensor body material

CPVC (polypropylene optional)

Sensing end material

Epoxy

Process connection

¾-inch male NPT thread at the rear of the sensor

 

 

Installation

Immersion installation

1-inch standpipe

In-line installation

Flow cell

Installation for micro air bubble applications

Flow cell with de-bubbler

Retractable installation

Valve retractable configuration

 

 

Electrical Connection and Communication

Communication

Digital

Electrical connection

Waterproof six-wire measuring cable

Cable lengths

10 ft (3.0 m), 20 ft (6.1 m) or 30 ft (9.1 m)

Compatible instruments

ECD T80 Transmitter and ECD LQ800 Multi-Channel Controller

 

 

Calibration

Factory calibration

According to the selected measurement range

Calibration method

Three-point calibration (0%, 50% and 100% of measurement range)

Turbidity calibration standards

Formazin, StablCal or SDVB beads

Suspended solids calibration

Actual process samples with known suspended solids concentrations

Drawing

Triton TR80 Turbidity Suspended Solids Sensor Drawing

Downloads

TR80 - Instruction Manual DownloadTR80 - Instruction Manual