ECD
CA6 Nickel Analyzer
Online colorimetric analyzer for automated measurement of nickel concentrations in water.
Measuring ranges: 0–3.0 mg/L, 0–30.0 mg/L or 0–150.0 mg/L (higher ranges require an optional dilution module)
LED light source and heated colorimetric reaction cell
Programmable analysis cycles and touchscreen interface
4–20 mA analog output and two configurable alarm relays
Separate lockable electrical and liquid compartments
Wall mounting or optional benchtop support
Overview
The ECD CA-6 Nickel Analyzer is an online sequential sampling analyzer designed for automated measurement of nickel concentrations in water using colorimetric technology. It incorporates an LED light source and a heated colorimetric reaction cell, using the difference between reference and reading measurements to determine nickel concentration based on stored calibration information. It is available in measuring ranges of 0–3.0 mg/L, 0–30.0 mg/L and 0–150.0 mg/L, with the two higher ranges requiring an optional dilution module.
The analyzer features programmable analysis cycles, a user-friendly touchscreen interface, a 4–20 mA analog output and two configurable alarm relays. Its epoxy powder-coated cold-rolled steel cabinet contains separate lockable electrical and liquid compartments. The factory-calibrated analyzer supports wall mounting or optional benchtop installation and operates at temperatures from 5 to 50 °C with a 110–220 VAC, 50–60 Hz power supply.
Typical Applications
Online monitoring of nickel concentrations in water
Automated water quality analysis at programmable intervals
Integration with process control and monitoring systems via 4–20 mA analog output
Key Features
Online sequential sampling using colorimetric technology
Nickel measuring ranges of 0–3.0, 0–30.0 or 0–150.0 mg/L (higher ranges require an optional dilution module)
LED light source and heated colorimetric reaction cell
Differential absorbance measurement using reference and reading values
Programmable analysis cycles with adjustable cycle time
User-friendly touchscreen interface
Factory-calibrated analyzer
4–20 mA analog output
Two configurable alarm relays, with loss of sample and low reagent alarm functions
Epoxy powder-coated cold-rolled steel cabinet
Separate lockable electrical and liquid compartments
Operating temperature range of 5–50 °C
Wall mounting or optional benchtop support
Benefits
Automated online analysis reduces the need for manual sampling and testing.
Differential absorbance measurement compensates for background interference from sample colour and turbidity.
Adjustable cycle time helps minimise reagent consumption.
User-friendly touchscreen interface simplifies operation and analysis configuration.
Factory calibration simplifies initial setup.
Optional dilution module extends the measurable nickel concentration range.
Separate electrical and liquid compartments keep electronic components apart from liquid-handling components.
Loss of sample and low reagent alarms provide notifications of operating issues.
4–20 mA analog output facilitates integration with external monitoring and control systems.
Flexible mounting options accommodate different installation requirements.
Specifications
Measurement | |
|---|---|
Measured parameter | Nickel |
Model number | CA6-11-X (X = A, B or C) |
Measurement method | Colorimetric differential absorbance |
Measuring range (A) | 0–3.0 mg/L |
Measuring range (B) | 0–30.0 mg/L |
Measuring range (C) | 0–150.0 mg/L |
Dilution module | Optional module with 10:1 or 50:1 dilution ratios; required for ranges B and C |
Response time | Dependent on the specific colorimetric measurement |
Repeatability | ±2% of absorbance value with turbidity <80 NTU |
Drift | ±2% per month on absorbance measurement |
Colorimetric Measurement System | |
|---|---|
Light source | Long-life LED |
Reaction cell | Heated quartz colorimetric reaction cell |
Optical detector | Photometer |
Measurement sequence | Reference measurement and reading measurement |
Calibration | Factory calibrated |
Operation and Reagent Consumption | |
|---|---|
Sampling method | Online sequential sampling |
User interface | Touchscreen |
Analysis configuration | Programmable |
Analysis cycle time | Adjustable |
Reagent consumption | Approximately 2,500 tests per litre of reagent, depending on the specific colorimetric measurement |
Outputs and Alarms | |
|---|---|
Analog output | 4–20 mA |
Alarm relays | 2 configurable relays |
Alarm functions | Loss of sample and low reagent |
Sample Requirements | |
|---|---|
Inlet sample pressure | Atmospheric |
Outlet sample pressure | Atmospheric |
Sample flow for fast loop reservoir | 100–500 mL/min |
Fast loop reservoir connection | Flexible tubing, ¼″ OD |
Waste tubing | ⅜″ OD |
Electrical | |
|---|---|
Power supply | 110–220 VAC, 50–60 Hz, 80 VA |
Operating Conditions | |
|---|---|
Operating temperature | 5–50 °C |
Physical and Mechanical | |
|---|---|
Cabinet material | Epoxy powder-coated cold-rolled steel |
Cabinet configuration | Separate electrical and liquid compartments with lockable doors |
Dimensions (L × H × D) | 380 × 600 × 210 mm (15 × 24 × 8.25″) |
Weight | Approximately 17 kg (37.5 lbs) |
Mounting | Wall mounting or optional benchtop support |
Drawing

Downloads
| CA6 - Nickel Analyzer Brochure | DownloadCA6 - Nickel Analyzer Brochure |
|---|
Related Products

ECD
CA6 Total Phosphate Analyzer
The CA-6 Total Phosphate Analyzer provides automated online colorimetric measurement of total phosphate in water, featuring sequential sampling, a touchscreen…
Learn More
ECD
CA6 Nitrite Analyzer
The CA-6 Nitrite Analyzer provides automated online nitrite measurement in water using colorimetric analysis, featuring low reagent consumption, automatic…
Learn More
ECD
CA6 Phosphate Analyzer
The CA-6 Phosphate Analyzer provides automatic online phosphate measurement in water using colorimetric analysis, featuring low reagent consumption, automatic…
Learn More
ECD
CA6 Hydrazine Analyzer
The CA-6 Hydrazine Analyzer provides automatic online colorimetric measurement of hydrazine in water, featuring low reagent consumption, automatic…
Learn More