WETEC

ECD

CA6 Nickel Analyzer

WaterWater Quality Measurement

Online colorimetric analyzer for automated measurement of nickel concentrations in water.

  • Measuring ranges: 0–3.0 mg/L, 0–30.0 mg/L or 0–150.0 mg/L (higher ranges require an optional dilution module)

  • LED light source and heated colorimetric reaction cell

  • Programmable analysis cycles and touchscreen interface

  • 4–20 mA analog output and two configurable alarm relays

  • Separate lockable electrical and liquid compartments

  • Wall mounting or optional benchtop support

Quantity
1

Overview

The ECD CA-6 Nickel Analyzer is an online sequential sampling analyzer designed for automated measurement of nickel concentrations in water using colorimetric technology. It incorporates an LED light source and a heated colorimetric reaction cell, using the difference between reference and reading measurements to determine nickel concentration based on stored calibration information. It is available in measuring ranges of 0–3.0 mg/L, 0–30.0 mg/L and 0–150.0 mg/L, with the two higher ranges requiring an optional dilution module.

The analyzer features programmable analysis cycles, a user-friendly touchscreen interface, a 4–20 mA analog output and two configurable alarm relays. Its epoxy powder-coated cold-rolled steel cabinet contains separate lockable electrical and liquid compartments. The factory-calibrated analyzer supports wall mounting or optional benchtop installation and operates at temperatures from 5 to 50 °C with a 110–220 VAC, 50–60 Hz power supply.

Typical Applications

  • Online monitoring of nickel concentrations in water

  • Automated water quality analysis at programmable intervals

  • Integration with process control and monitoring systems via 4–20 mA analog output

Key Features

  • Online sequential sampling using colorimetric technology

  • Nickel measuring ranges of 0–3.0, 0–30.0 or 0–150.0 mg/L (higher ranges require an optional dilution module)

  • LED light source and heated colorimetric reaction cell

  • Differential absorbance measurement using reference and reading values

  • Programmable analysis cycles with adjustable cycle time

  • User-friendly touchscreen interface

  • Factory-calibrated analyzer

  • 4–20 mA analog output

  • Two configurable alarm relays, with loss of sample and low reagent alarm functions

  • Epoxy powder-coated cold-rolled steel cabinet

  • Separate lockable electrical and liquid compartments

  • Operating temperature range of 5–50 °C

  • Wall mounting or optional benchtop support

Benefits

  • Automated online analysis reduces the need for manual sampling and testing.

  • Differential absorbance measurement compensates for background interference from sample colour and turbidity.

  • Adjustable cycle time helps minimise reagent consumption.

  • User-friendly touchscreen interface simplifies operation and analysis configuration.

  • Factory calibration simplifies initial setup.

  • Optional dilution module extends the measurable nickel concentration range.

  • Separate electrical and liquid compartments keep electronic components apart from liquid-handling components.

  • Loss of sample and low reagent alarms provide notifications of operating issues.

  • 4–20 mA analog output facilitates integration with external monitoring and control systems.

  • Flexible mounting options accommodate different installation requirements.

Specifications

Measurement

Measured parameter

Nickel

Model number

CA6-11-X (X = A, B or C)

Measurement method

Colorimetric differential absorbance

Measuring range (A)

0–3.0 mg/L

Measuring range (B)

0–30.0 mg/L

Measuring range (C)

0–150.0 mg/L

Dilution module

Optional module with 10:1 or 50:1 dilution ratios; required for ranges B and C

Response time

Dependent on the specific colorimetric measurement

Repeatability

±2% of absorbance value with turbidity <80 NTU

Drift

±2% per month on absorbance measurement

 

 

Colorimetric Measurement System

Light source

Long-life LED

Reaction cell

Heated quartz colorimetric reaction cell

Optical detector

Photometer

Measurement sequence

Reference measurement and reading measurement

Calibration

Factory calibrated

 

 

Operation and Reagent Consumption

Sampling method

Online sequential sampling

User interface

Touchscreen

Analysis configuration

Programmable

Analysis cycle time

Adjustable

Reagent consumption

Approximately 2,500 tests per litre of reagent, depending on the specific colorimetric measurement

 

 

Outputs and Alarms

Analog output

4–20 mA

Alarm relays

2 configurable relays

Alarm functions

Loss of sample and low reagent

 

 

Sample Requirements

Inlet sample pressure

Atmospheric

Outlet sample pressure

Atmospheric

Sample flow for fast loop reservoir

100–500 mL/min

Fast loop reservoir connection

Flexible tubing, ¼″ OD

Waste tubing

⅜″ OD

 

 

Electrical

Power supply

110–220 VAC, 50–60 Hz, 80 VA

 

 

Operating Conditions

Operating temperature

5–50 °C

 

 

Physical and Mechanical

Cabinet material

Epoxy powder-coated cold-rolled steel

Cabinet configuration

Separate electrical and liquid compartments with lockable doors

Dimensions (L × H × D)

380 × 600 × 210 mm (15 × 24 × 8.25″)

Weight

Approximately 17 kg (37.5 lbs)

Mounting

Wall mounting or optional benchtop support

Drawing

CA6 Nickel Analyzer Drawing

Downloads

CA6 - Nickel Analyzer Brochure DownloadCA6 - Nickel Analyzer Brochure