WETEC

ECD

CA6 Total Phosphate Analyzer

WaterWater Quality Measurement

Online sequential sampling analyzer for total phosphate measurement in water using colorimetric technology.

  • LED light source and heated colorimetric reaction cell

  • User-friendly touchscreen interface

  • 4–20 mA analog output and two configurable alarm relays

  • Adjustable cycle time to minimize reagent consumption

  • Epoxy powder-coated steel cabinet with separate electrical and liquid compartments

Quantity
1

Overview

The ECD CA-6 Total Phosphate Analyzer is an online sequential sampling analyzer designed to measure total phosphate concentrations in water using colorimetric technology. It utilizes an LED light source and a heated colorimetric reaction cell for automated analysis. The concentration is determined from the difference between the reference and color-developed absorbance measurements using stored calibration information.

The analyzer features a user-friendly touchscreen interface, programmable analysis sequences and adjustable cycle times to minimize reagent consumption. Its rugged, epoxy powder-coated cold-rolled steel cabinet contains separate lockable electrical and liquid compartments. The instrument provides a 4–20 mA analog output, two configurable alarm relays, and loss-of-sample and low-reagent alarms. It operates on a 110–220 VAC, 50–60 Hz power supply and supports wall mounting or an optional benchtop stand.

Typical Applications

  • Online monitoring of total phosphate concentrations in water

  • Analog signal integration with process control and monitoring systems

Key Features

  • Online sequential sampling with automated colorimetric analysis

  • LED light source and heated colorimetric reaction cell

  • Differential absorbance measurement using reference and reading values

  • Factory-calibrated analyzer

  • Touchscreen interface with programmable analysis sequences and adjustable cycle time

  • Loss-of-sample and low-reagent alarms

  • 4–20 mA analog output

  • Two configurable alarm relays

  • Epoxy powder-coated cold-rolled steel cabinet with separate lockable electrical and liquid compartments

  • Operating temperature range of 5…50 °C

  • Power supply of 110–220 VAC, 50–60 Hz, 80 VA

  • Wall mounting with optional benchtop support

Benefits

  • Automated analysis reduces the need for manual sampling and measurement

  • Reference measurement compensates for sample color, turbidity and optical interference

  • Simplified startup with factory calibration

  • Easy operation and process configuration through the touchscreen interface

  • Adjustable cycle times help minimize reagent consumption

  • Low maintenance requirements reduce routine servicing needs

  • Rugged cabinet construction protects internal components

  • Loss-of-sample and low-reagent alarms provide operational alerts

  • Flexible installation with standard wall mounting or optional benchtop support

Specifications

Measurement and Analysis

Measured parameter

Total Phosphate

Measurement method

Colorimetric differential absorbance using reference and reading measurements

Sampling method

Online sequential sampling

Light source

Long-life LED

Optical detector

Photometer

Reaction cell

Heated quartz colorimetric reaction cell

Repeatability

±2% on absorbance value with turbidity below 80 NTU

Drift

±2% per month on absorbance measurement

Response time

Dependent on the specific colorimetric measurement

 

 

Analysis Configuration

Calibration

Factory calibrated

Analysis cycle time

Adjustable

User interface

Touchscreen

Menu options

RUN, DISPLAY, PROGRAM, SERVICE and HELP

Additional cycle

User-defined calibration or cleaning sequence

Reagent consumption

Approximately 2,500 tests per litre of reagent, dependent on the specific colorimetric measurement

Optional dilution module

10:1 or 50:1 dilution ratios for higher-range samples

 

 

Sample Requirements

Inlet sample pressure

Atmospheric

Outlet sample pressure

Atmospheric

Sample flow for fast loop reservoir

100–500 mL/min

Fast loop reservoir connection

Flexible tubing, ¼″ O.D.

Waste tubing

⅜″ O.D.

 

 

Outputs and Alarms

Analog output

4–20 mA

Alarm relays

Two configurable relays

Alarm functions

Loss of sample and low reagent

 

 

Electrical

Power supply

110–220 VAC

Frequency

50–60 Hz

Power rating

80 VA

 

 

Operating Conditions

Operating temperature

5…50 °C

 

 

Mechanical

Dimensions (L × H × D)

380 × 600 × 210 mm (15 × 24 × 8.25″)

Weight

Approximately 17 kg (37.5 lbs)

Cabinet material

Epoxy powder-coated cold-rolled steel

Enclosure configuration

Separate electrical and liquid compartments with lockable doors

Mounting

Wall mounting or optional benchtop support

Drawing

CA6 Total Phosphate Analyzer Drawing

Downloads