ECD
CA6 Phosphate Analyzer
Online colorimetric analyzer for automatic phosphate measurement in water using the Yellow Method.
Measuring range up to 2000 mg/L PO₄ with internal dilution
Automatic calibration, validation and cleaning
Low reagent consumption with programmable analysis frequency
Colour touchscreen interface with integrated data logger
Two 4–20 mA outputs and Modbus RTU RS485 communication
Dual-compartment enclosure with IP54 protection
Overview
The ECD CA-6 Phosphate Analyzer is an online sequential sampling analyzer designed for automatic phosphate measurement in water using the colorimetric Yellow Method. It uses an LED light source and a heated colorimetric reaction cell to determine phosphate concentration through differential photometric absorbance at 430 nm, with a measuring range of up to 2000 mg/L PO₄ when equipped with an internal dilution module.
The analyzer features programmable analysis intervals, automatic calibration, validation and cleaning, and low reagent consumption. It incorporates a colour touchscreen interface with an integrated data logger and USB data download, two 4–20 mA outputs, and Modbus RTU RS485 communication. The rugged IP54-rated cabinet features two separate compartments to isolate the electronic components from the liquid handling system.
Typical Applications
Phosphate monitoring in power utility water systems
Phosphate concentration measurement in cooling water
Drinking water quality monitoring
Phosphate monitoring in boiler feedwater
Industrial and municipal wastewater monitoring
Surface water quality monitoring
Key Features
Online colorimetric measurement using the Yellow Method at 430 nm
Measuring range of up to 2000 mg/L PO₄ with internal dilution
LED light source with heated colorimetric reaction cell
Programmable analysis frequency with an 8–10 minute cycle, including conditioning and rinsing
Automatic calibration, validation and cleaning
Single-reagent configuration with low reagent consumption
Colour touchscreen interface with multilingual menu
Integrated data logger with USB data download
Two 4–20 mA outputs and Modbus RTU RS485 communication
Four programmable SPDT alarm relays
Digital input for remote start and stop
Up to four sample streams with an external sequencer
Rugged epoxy powder-coated steel cabinet with separate liquid and electronic compartments
IP54 enclosure protection
Standard 100–240 VAC, 50/60 Hz power supply, with optional 24 VDC
Benefits
Automated phosphate monitoring reduces the need for manual sampling and analysis.
Low reagent consumption and adjustable analysis intervals minimise operating costs.
Automatic calibration, validation and cleaning reduce downtime and operator intervention.
Wide measuring range accommodates varying phosphate concentrations.
Separate compartments isolate electronic components from the liquid handling system.
User-friendly touchscreen simplifies operation and configuration.
Analogue and digital outputs facilitate integration with external monitoring and control systems.
Optional multi-stream configurations enable monitoring of different sampling points.
Factory-tested design simplifies installation and commissioning.
Specifications
Measurement | |
|---|---|
Measured parameter | Phosphates / reactive phosphorus (PO₄ / P-PO₄) |
Measurement units | ppb, ppm, mg/L |
Measuring principle | Differential photometric absorbance (Yellow Method) |
Measurement wavelength | 430 nm |
Measuring range (26 mm cell) | 0.05–10 ppm P-PO₄ (30 ppm PO₄) |
Measuring range (16 mm cell) | 0.1–16 ppm P-PO₄ (50 ppm PO₄) |
Measuring range with internal dilution | Up to 640 ppm P-PO₄ / 2000 ppm PO₄ |
Reproducibility (26 mm cell) | ±200 ppb or ±5%, whichever is greater |
Reproducibility (16 mm cell) | ±500 ppb or ±5%, whichever is greater |
Analysis and Operation | |
|---|---|
Analysis frequency | Freely programmable, batch near-continuous analysis |
Cycle time | 8–10 minutes, including conditioning before analysis and rinsing after measurement |
Reaction cell | Heated |
Calibration | Automatic, with selectable intervals |
Validation | Automatic, with selectable intervals |
Cleaning | Automatic, with selectable intervals |
Reagent Configuration and Consumption | |
|---|---|
Reagent configuration | Single reagent |
Reagent consumption (16 mm cell) | 2.5 L (0.66 US gal) every 90 days at a 15-minute analysis interval |
Reagent consumption (26 mm cell) | 5 L (1.32 US gal) every 90 days at a 15-minute analysis interval |
Sample Requirements | |
|---|---|
Sample supply | Pressure-free from overflow vessel |
Sample temperature | 5–50 °C (41–122 °F) |
Sample flow rate | 80–500 mL/min |
Sample connection | 6 mm (¼ in.) |
Drain Requirements | |
|---|---|
Drain type | Pressure-free, atmospheric drain |
Drain connection | 12 mm (½ in.) |
Sample Streams | |
|---|---|
Number of sample streams | 1 or 2 (dual-stream version with integrated switching valve); 3 or 4 with external sequencer |
Display and Data Management | |
|---|---|
Display | Colour graphic touchscreen |
Display information | Measured values and status information |
Interface languages | Multiple languages |
Data logger | Integrated |
Data download | USB |
Outputs, Inputs and Alarms | |
|---|---|
Analogue outputs | 2 × 4–20 mA for measured data |
Digital communication | Modbus RTU RS485 |
Alarm relays | 4 programmable SPDT potential-free relays |
Digital input | Remote start/stop |
Power Supply | |
|---|---|
Standard power supply | 100–240 VAC, 50/60 Hz |
Optional power supply | 24 VDC |
Maximum power consumption | 80 VA |
Environmental Conditions | |
|---|---|
Operating temperature | 5–45 °C (41–113 °F) |
Relative humidity | 10–90%, non-condensing |
Operating environment | Indoor use |
Outdoor installation | Protective cabinet or shelter required (not included) |
Physical | |
|---|---|
Enclosure configuration | Dual compartments separating electronic and liquid handling components |
Ingress protection | IP54 |
Dimensions (H × W × D) | 606 × 380 × 209 mm / 23.6 × 15.0 × 8.2 in. |
Weight | Approximately 20 kg (44 lbs) |
Installation | |
|---|---|
Standard mounting | Wall mounting |
Optional mounting | Benchtop support or panel mounting |
Drawing

Downloads
| CA6 - Phosphate Analyzer Brochure | DownloadCA6 - Phosphate Analyzer Brochure |
|---|
Related Products

ECD
CA6 Total Phosphate Analyzer
The CA-6 Total Phosphate Analyzer provides automated online colorimetric measurement of total phosphate in water, featuring sequential sampling, a touchscreen…
Learn More
ECD
CA6 Nickel Analyzer
The CA-6 Nickel Analyzer uses online colorimetric technology for automated nickel measurement in water, featuring programmable analysis cycles and a…
Learn More
ECD
CA6 Nitrite Analyzer
The CA-6 Nitrite Analyzer provides automated online nitrite measurement in water using colorimetric analysis, featuring low reagent consumption, automatic…
Learn More
ECD
CA6 Hydrazine Analyzer
The CA-6 Hydrazine Analyzer provides automatic online colorimetric measurement of hydrazine in water, featuring low reagent consumption, automatic…
Learn More