WETEC

ECD

CA6 Nitrite Analyzer

WaterWater Quality Measurement

Compact online colorimetric analyzer for automatic nitrite measurement in water.

  • Measuring range from trace µg/L up to 125 mg/L NO₂ with internal dilution

  • Automatic calibration, validation and cleaning

  • Low reagent consumption and adjustable analysis frequency

  • Colour touchscreen interface with integrated data logger

  • Two 4–20 mA outputs and Modbus RTU RS485 communication

  • Dual-compartment enclosure with IP54 protection

Quantity
1

Overview

The ECD CA-6 Nitrite Analyzer is a compact online colorimetric analyzer designed for automatic nitrite measurement in water. It performs sequential sampling and analysis using an LED light source and a heated colorimetric reaction cell. The analyzer determines nitrite concentration through differential photometric absorbance at 525 nm, with measuring ranges from trace µg/L up to 125 mg/L NO₂ using internal dilution.

The analyzer features a dual-compartment enclosure that separates the electronic and liquid-handling components. It incorporates automatic calibration, validation and cleaning functions, programmable analysis frequency and low reagent consumption. A colour touchscreen interface provides access to measured values, operating status and configuration settings, while an integrated data logger supports USB data download. The analyzer is equipped with two 4–20 mA outputs, Modbus RTU RS485 communication and four programmable SPDT alarm relays, with an IP54-rated enclosure.

Typical Applications

  • Nitrite monitoring in drinking water

  • Process optimisation in wastewater treatment plants

  • Nitrite monitoring in industrial and municipal wastewater

  • Mineral water quality monitoring

  • Nitrite monitoring in surface water

Key Features

  • Online sequential colorimetric measurement using differential photometric absorbance at 525 nm

  • Measuring range from trace µg/L up to 125 mg/L NO₂ with internal dilution

  • LED light source and heated colorimetric reaction cell

  • Automatic calibration, validation and cleaning with selectable intervals

  • Programmable analysis frequency with a 6–8 minute analysis cycle

  • Colour touchscreen interface with multilingual menu navigation

  • Integrated data logger with USB data download

  • Two 4–20 mA outputs and Modbus RTU RS485 communication

  • Four programmable SPDT potential-free alarm relays

  • Loss of sample and low reagent alarms

  • Up to four sample streams with an external sequencer

  • IP54-rated epoxy powder-coated steel cabinet with separate electronic and liquid-handling compartments

  • Standard wall mounting with optional benchtop or panel mounting

Benefits

  • Automated analysis, calibration, validation and cleaning reduce downtime and operator intervention

  • Low reagent consumption and adjustable analysis frequency help minimise operating costs

  • Reference measurements minimise interference from sample colour, turbidity and refractive index variations

  • Wide measuring range accommodates different nitrite concentrations

  • User-friendly touchscreen simplifies operation and configuration

  • Integrated data logging enables convenient data retrieval

  • Optional multiple-stream configurations allow monitoring of different sampling points

  • Separate compartments isolate electronics from liquid-handling components

  • Factory-tested design simplifies installation and commissioning

  • Loss of sample and low reagent alarms alert operators to operating issues

Specifications

Measurement

Measured parameter

NO₂ / N-NO₂

Measurement units

ppb, ppm, mg/L

Measuring principle

Differential photometric absorbance (diazotization)

Measurement wavelength

525 nm

Light source

LED

Measuring range (26 mm cell)

5–500 ppb N-NO₂ (1.6 ppm NO₂ at upper limit)

Measuring range (16 mm cell)

0.02–1 ppm N-NO₂ (3.2 ppm NO₂ at upper limit)

Measuring range with internal dilution

Up to 40 ppm N-NO₂ / 125 ppm NO₂

Reproducibility (up to 150 ppb, 26 mm cell)

±5 ppb or ±5%, whichever is greater

Reproducibility (≥150 ppb to 600 ppb)

±10 ppb

Reproducibility (≥600 µg/L, 16 mm cell)

±20 ppb or ±5%, whichever is greater

 

 

Analysis and Operation

Analysis frequency

Freely programmable, batch near-continuous analysis

Cycle time

6–8 minutes, including conditioning before analysis and rinsing after measurement

Reaction cell

Heated colorimetric reaction cell

Calibration

Automatic, with selectable intervals

Validation

Automatic, with selectable intervals

Cleaning

Automatic, with selectable intervals

 

 

Sample and Drain Requirements

Sample pressure

Pressure-free from overflow vessel

Sample temperature

5–50 °C (41–122 °F)

Sample flow rate

80–500 mL/min

Sample connection

6 mm (¼ in.)

Drain condition

Pressure-free, atmospheric drain

Drain connection

12 mm (½ in.)

Number of sample streams

1 or 2 with integrated switching valve; 3 or 4 with external sequencer

 

 

Reagent Consumption

Reagent consumption (16 mm cell)

0.7 L (0.18 US gal) per reagent every 30 days at a 15-minute analysis frequency

Reagent consumption (26 mm cell)

1 L (0.26 US gal) per reagent every 30 days at a 15-minute analysis frequency

 

 

Display and Data Management

User interface

Colour graphic touchscreen

Display information

Measured values and status information

Language support

Multiple languages

Data logging

Integrated data logger

Data download

USB

 

 

Outputs, Communication and Alarms

Analogue outputs

2 × 4–20 mA for measured data

Digital communication

Modbus RTU RS485

Alarm relays

4 programmable SPDT potential-free relays

Alarm functions

Loss of sample and low reagent

Digital input

Remote start/stop

 

 

Power Supply

Standard power supply

100–240 VAC, 50/60 Hz

Optional power supply

24 VDC

Power consumption

Maximum 80 VA

 

 

Environmental Conditions

Operating temperature

5–45 °C (41–113 °F)

Relative humidity

10–90%, non-condensing

Operating environment

Indoor use; outdoor installation requires a protective cabinet or shelter (not included)

 

 

Mechanical and Installation

Cabinet construction

Epoxy powder-coated cold-rolled steel

Enclosure design

Separate electronic and liquid-handling compartments

Cabinet doors

Two lockable doors

Dimensions (H × W × D)

606 × 380 × 209 mm / 23.6 × 15.0 × 8.2 in.

Weight

Approximately 20 kg (44 lbs)

Ingress protection

IP54

Standard installation

Wall mounting

Optional installation

Benchtop support or panel mounting

Drawing

CA6 Nitrite  Analyzer Drawing

Downloads

CA6 - Nitrite Analyzer Brochure DownloadCA6 - Nitrite Analyzer Brochure