WETEC

ECD

CA6 Zinc Analyzer


Compact online colorimeter for the automatic measurement of dissolved Zinc in water

  • The determination ranges of the CA6 Zinc Analyzer vary from trace μg/L to 125 mg/L Zn2+ using internal dilution module

  • 2 x 4-20 mA outputs for measured data Modbus RTU RS485

  • Automatic calibration, validation and cleaning, with colour touchscreen and USB datalogger

Quantity
1

Overview

The Model CA-6 Zinc Analyzer is an automated online system for continuous water monitoring, using colorimetric analysis with an LED light source and a heated reaction cell. Its dual-enclosure design keeps the top electrical section completely isolated from the bottom liquids section.

During operation, the system performs a smart reference measurement after adding initial reagents to eliminate background sample color, turbidity, and refractive index variations. It then adds color-producing reagents, mixes the sample, takes the final reading to calculate concentration, and automatically drains and rinses the cell between cycles.

The CA-6 can also be configured to measure: Aluminum, Ammonia, Chlorine, Chloride, Chromium VI, Copper, Cyanide, Hardness, Iron, Manganese, Nickel, Nitrate, Nitrite, Phosphate, Total Phosphate, Silica, Sulfate, Zinc.

Typical Applications

  • Drinking water

  • Industrial waste water

  • Effluent water

  • Surface water

  • Boilers and cooling towers

Key Features

  • Wide Measuring Range: Measures from trace µg/L up to 125 mg/L $\text{Zn}^{2+}$ using the internal dilution module

  • Color Touchscreen Interface: Features an intuitive graphic display with multi-language support, easy menu access, and a USB datalogger

  • Automatic Calibration & Cleaning: Automated validation, cleaning, and calibration reduce downtime and ensure accuracy

  • Multiple Streams: Supports dual streams natively, with expansion up to 4 streams using an external sequencer

Benefits

  • Dual-Compartment Enclosure: Ensures complete physical separation between the electronics and the wet part

  • Low Reagent Consumption: Minimizes operating costs with low reagent usage—only 1.1 L (0.29 US gal) for the 16 mm cell or 2.0 L (0.53 US gal) for the 26 mm cell of each reagent every 30 days at a 15-minute analysis frequency

  • Factory Tested, Ready for Installation and Operation: Fully operational right out of the box—just connect the power, sample, and reagent lines

Typical Applications

MEASUREMENT

 

Measured parameter

Zn2+ (ppb, ppm, mg/l

Measuring principle

Differential photometric absorbance. Zincon method

Measuring range

0.01 to 1 ppm Zn2+ for the 26 mm cell

0.02 to 2.5 ppm Zn2+ for the 16 mm cell

up to 125 ppm Zn2+ with internal dilution

Reproducibility

± 10 ppb or ± 5%, whichever is greater (26 mm cell)

± 20 ppb or ± 5%, whichever is greater (16 mm cell)

Analysis frequency

Freely programmable, batch near-continuous analysis

Cycle time

6-8 minutes, including conditioning before analysis cycle and rinsing after measuring

Reaction cell

Temperature heated

 

 

SAMPLE & STREAMS

 

Sample

Pressure-free from overflow

vessel Temperature: 41 - 122 °F (5 to 50 °C)

Flow Rate: 80 to 500 mL/min

Connection: 6 mm (¼-in.)

Drain

Pressure-free, atmospheric drain

Connection: 12 mm (½-in.)

Number of streams

1, 2 with integrated switching valve
3, 4 with external sequencer

Reagent consumption

1.1L (0.29 US gal) for the 16 mm cell / 2.0L (0.53 US gal) for the 26 mm cell of each reagent every 30 days with 15 minute analysis frequency

 

 

ELECTRICAL

 

Power supply

Voltage: 100 - 240 VAC 50/60 Hz standard or 24 VDC (option)

Power consumption: max. 80 VA

Outputs

2 x 4-20 mA outputs for measured data

Modbus RTU RS485

Alarms

4 SPDT programmable potential free relays

Digital input

Remote start / stop

User interface

Colour graphic touchscreen, multiple languages, integrated datalogger with USB download

 

 

PHYSICAL & ENVIRONMENTAL

 

Dimensions (H x W x D)

23.6 x 15.0 x 8.2 in / 606 x 380 x 209 mm

Weight

Approx. 44 lbs (20 Kg)

Operating temperature

41 - 113 °F (5 - 45 °C)

Humidity

10 to 90% non-condensing (indoor use, outdoor installation only possible with protective cabinet or shelter not included)

Installation

Wall mount (standard), bench top support or panel mount (options)

Ingress protection

IP54