ECD
CA6 Zinc Analyzer
Compact online colorimeter for the automatic measurement of dissolved Zinc in water
The determination ranges of the CA6 Zinc Analyzer vary from trace μg/L to 125 mg/L Zn2+ using internal dilution module
2 x 4-20 mA outputs for measured data Modbus RTU RS485
Automatic calibration, validation and cleaning, with colour touchscreen and USB datalogger
Overview
The Model CA-6 Zinc Analyzer is an automated online system for continuous water monitoring, using colorimetric analysis with an LED light source and a heated reaction cell. Its dual-enclosure design keeps the top electrical section completely isolated from the bottom liquids section.
During operation, the system performs a smart reference measurement after adding initial reagents to eliminate background sample color, turbidity, and refractive index variations. It then adds color-producing reagents, mixes the sample, takes the final reading to calculate concentration, and automatically drains and rinses the cell between cycles.
The CA-6 can also be configured to measure: Aluminum, Ammonia, Chlorine, Chloride, Chromium VI, Copper, Cyanide, Hardness, Iron, Manganese, Nickel, Nitrate, Nitrite, Phosphate, Total Phosphate, Silica, Sulfate, Zinc.
Typical Applications
Drinking water
Industrial waste water
Effluent water
Surface water
Boilers and cooling towers
Key Features
Wide Measuring Range: Measures from trace µg/L up to 125 mg/L $\text{Zn}^{2+}$ using the internal dilution module
Color Touchscreen Interface: Features an intuitive graphic display with multi-language support, easy menu access, and a USB datalogger
Automatic Calibration & Cleaning: Automated validation, cleaning, and calibration reduce downtime and ensure accuracy
Multiple Streams: Supports dual streams natively, with expansion up to 4 streams using an external sequencer
Benefits
Dual-Compartment Enclosure: Ensures complete physical separation between the electronics and the wet part
Low Reagent Consumption: Minimizes operating costs with low reagent usage—only 1.1 L (0.29 US gal) for the 16 mm cell or 2.0 L (0.53 US gal) for the 26 mm cell of each reagent every 30 days at a 15-minute analysis frequency
Factory Tested, Ready for Installation and Operation: Fully operational right out of the box—just connect the power, sample, and reagent lines
Typical Applications
MEASUREMENT |
|
Measured parameter | Zn2+ (ppb, ppm, mg/l |
Measuring principle | Differential photometric absorbance. Zincon method |
Measuring range | 0.01 to 1 ppm Zn2+ for the 26 mm cell 0.02 to 2.5 ppm Zn2+ for the 16 mm cell up to 125 ppm Zn2+ with internal dilution |
Reproducibility | ± 10 ppb or ± 5%, whichever is greater (26 mm cell) ± 20 ppb or ± 5%, whichever is greater (16 mm cell) |
Analysis frequency | Freely programmable, batch near-continuous analysis |
Cycle time | 6-8 minutes, including conditioning before analysis cycle and rinsing after measuring |
Reaction cell | Temperature heated |
SAMPLE & STREAMS |
|
Sample | Pressure-free from overflow vessel Temperature: 41 - 122 °F (5 to 50 °C) Flow Rate: 80 to 500 mL/min Connection: 6 mm (¼-in.) |
Drain | Pressure-free, atmospheric drain Connection: 12 mm (½-in.) |
Number of streams | 1, 2 with integrated switching valve |
Reagent consumption | 1.1L (0.29 US gal) for the 16 mm cell / 2.0L (0.53 US gal) for the 26 mm cell of each reagent every 30 days with 15 minute analysis frequency |
ELECTRICAL |
|
Power supply | Voltage: 100 - 240 VAC 50/60 Hz standard or 24 VDC (option) Power consumption: max. 80 VA |
Outputs | 2 x 4-20 mA outputs for measured data Modbus RTU RS485 |
Alarms | 4 SPDT programmable potential free relays |
Digital input | Remote start / stop |
User interface | Colour graphic touchscreen, multiple languages, integrated datalogger with USB download |
PHYSICAL & ENVIRONMENTAL |
|
Dimensions (H x W x D) | 23.6 x 15.0 x 8.2 in / 606 x 380 x 209 mm |
Weight | Approx. 44 lbs (20 Kg) |
Operating temperature | 41 - 113 °F (5 - 45 °C) |
Humidity | 10 to 90% non-condensing (indoor use, outdoor installation only possible with protective cabinet or shelter not included) |
Installation | Wall mount (standard), bench top support or panel mount (options) |
Ingress protection | IP54 |
Drawing

Downloads
| CA6 Zinc Analyzer Datasheet (EN) | DownloadCA6 Zinc Analyzer Datasheet (EN) |
|---|
Related Products

ECD
UV6 UV Analyzer
Online UV-absorption analyzer measuring nitrate, COD/BOD/TOC (UV254 correlation) and colour (Pt-Co) across wide ranges.
Learn More
ECD
CE800 Cation Conductivity Analyzer
Measures conductivity after a cation exchange resin to detect contaminants in power plant makeup water, feedwater and condensate
Learn More
ECD
NA6 Sodium Analyzer
Ion-selective sodium analyzer, 10 ppb–10 ppm, for ultrapure water, power plant water/steam cycles and demin plant monitoring.
Learn More
ECD
CA900 Sulfide Ion Analyzer
Online sequential-sampling analyzer for sulfide in wastewater, refinery and industrial process streams (odour/corrosion control).
Learn More