Autonomous data logger for water level monitoring in narrow pipes from 2".
0/4…20 mA, RS485 Modbus RTU and switch/counter inputs
Bluetooth® configuration and optional 4G/2G remote data transmission
Non-volatile memory for at least 800,000 measured values
Alarm management for flooding and low water levels
IP68 housing, submersible up to 3 m
Lithium battery, rechargeable Li-ion battery and DC supply options, with PV charging for the Li-ion battery
Overview
The Senseca Hydrolog® HLF4 is an autonomous data logger designed for water level monitoring in narrow pipes from 2". It records measured values from connected level probes, ultrasonic sensors, radar sensors and similar measuring devices. It supports 0/4…20 mA analogue inputs, RS485 Modbus RTU interfaces and a digital switch/counter input, with integrated temporary sensor power supply and non-volatile memory for at least 800,000 measured values.
The data logger supports Bluetooth® configuration and optional remote data transmission to a web portal or FTP server via LTE-M1, LTE-NB2 or EGPRS cellular networks. It features alarm management for flooding and low water levels, together with an IP68 housing that withstands submersion up to 3 m. Power supply options include lithium batteries, a rechargeable Li-ion battery and external DC supply, with photovoltaic charging available for the rechargeable battery configuration.
Typical Applications
Water level monitoring in water and wastewater systems
Environmental water level monitoring
Long-term water level monitoring at hydroelectric power plants
Flood and low water level alerting
Water level monitoring for weir control
Storage tank level monitoring and inventory management
Water level monitoring in industrial processes
Key Features
Compact Ø 48 mm housing for installation in water level pipes from 2"
Supports up to 5 connected sensors and 11 measured variables
Two 0/4…20 mA analogue inputs, two RS485 Modbus RTU interfaces and one digital switch/counter input
Four temporary sensor power supply outputs: two 16.6 V and two 6.7 V
Non-volatile Dataflash memory with 8 MB capacity for at least 800,000 measured values
Bluetooth® 5.2 interface for local configuration and operation
Optional remote data transmission to a web portal or FTP server via LTE-M1, LTE-NB2 or EGPRS
Alarm management for flooding and low water levels
IP68 housing, submersible up to 3 m
Ambient temperature range -20…+60 °C
19 Ah or 35 Ah lithium battery, 20 Ah rechargeable Li-ion battery and 7…32 Vdc supply options
Photovoltaic charging support for the rechargeable Li-ion battery configuration
Quartz-based timekeeping with support for daily Internet time synchronization
Benefits
Compact design allows installation in narrow water level pipes
Flexible sensor compatibility simplifies integration with different monitoring systems
Integrated sensor power supply reduces the need for separate sensor power sources
Optional remote data transmission reduces the need for routine site visits
Wireless Bluetooth® configuration simplifies local operation
Non-volatile memory retains recorded measurement data during power interruptions
Alarm management enables timely reporting of flooding and low water levels
Submersible housing provides protection in flood-prone locations
Flexible power supply options accommodate different installation requirements
Energy-efficient design supports long-term autonomous monitoring
Specifications
Auxiliary Power Supply | |
|---|---|
Lithium battery (B1) | 3.6 V, 19 Ah |
Lithium battery (B2) | 3.6 V, 35 Ah |
Rechargeable Li-ion battery (A1) | 4.1 V, 20 Ah |
DC supply | 7…32 Vdc / ≤350 mA |
PV module (A1 configuration) | 4.5…32 Vdc / ≤2 A |
Analogue Inputs – Current | |
|---|---|
Input channels | Ai1 / Ai2 |
Signal range | 0/4…20 mA |
Full-scale input (FSI) | 0…28 mA |
Input resistance | 27 Ω |
Resolution | 16 bits FSI |
Characteristic curve deviation | ≤±0.05% FSI |
Temperature deviation | ≤±0.1% FSI / 10 K |
Long-term drift | ≤±0.05% FSI/year |
Communication Inputs – RS485 Modbus RTU | |
|---|---|
Interface channels | Ci1 / Ci2 |
Interface | RS485, bidirectional |
Communication protocol | Modbus RTU |
Baud rate | 9600 baud (4800…38400 baud) |
Input resistance | 96 kΩ |
Digital Input – Switch / Counter | |
|---|---|
Input channel | Di1 |
Input type | Switch / Counter |
Operating resistance | ≤20 kΩ |
Operating frequency | ≤1 kHz |
Transmitter Power Supply | |
|---|---|
Supply function | Temporary sensor power supply |
Output voltage (Uo1 / Uo2) | 16.6 V ±0.3 V (0 mA); 15.9 V ±0.3 V (30 mA) |
Output current (Uo1 / Uo2) | 0…30 mA, max. 40 mA |
Output voltage (Uo3 / Uo4) | 6.7 V ±0.2 V (0 mA); 6.6 V ±0.2 V (100 mA) |
Output current (Uo3 / Uo4) | 0…100 mA, max. 300 mA |
Bluetooth Interface | |
|---|---|
Standard | Bluetooth® 5.2 |
Data rate | 2 Mbit/s |
Advertising mode | 2 s |
Transmit power | ≤0.1 W |
Outdoor range | Max. 200 m |
Indoor range | Max. 40 m |
Cellular Communication Interface (Optional) | |
|---|---|
Communication standards | 4G LTE-M1, 4G LTE-NB2 (NB-IoT), 2G EGPRS |
LTE-M1 frequency bands (LTE-FDD) | B1/B2/B3/B4/B5/B8/B12/B13/B18/B19/B20/B25/B26/B27/B28/B66/B85 |
LTE-NB2 frequency bands (LTE-FDD) | B1/B2/B3/B4/B5/B8/B12/B13/B18/B19/B20/B25/B28/B66/B71/B85 |
EGPRS frequency bands | 850/900/1800/1900 MHz |
Network priority | 4G (LTE-M1 or LTE-NB2), fallback to 2G (EGPRS) |
4G transmit power | ≤0.2 W |
2G transmit power | ≤2 W |
SIM | Internal SIM + external Micro-SIM |
Antenna connector | SMA connector / 50 Ω |
Remote data destination | Web portal or FTP server |
Data Logger – Memory | |
|---|---|
Memory type | Non-volatile Dataflash |
Memory capacity | 8 MB |
Storage capacity | ≥800,000 measured values |
Data Logger – Time | |
|---|---|
Time accuracy with Internet synchronization | ≤±4 s/month |
Internet time synchronization | Once daily |
Time accuracy without Internet synchronization | ≤±2 min/month |
Frequency standard | Quartz |
Environmental Conditions | |
|---|---|
Ambient temperature | −20…+60 °C |
Li-ion battery charging temperature (A1) | 0…+45 °C, internally limited |
Ingress protection | IP68 (EN/IEC 60529) |
Submersion depth | ≤3 m |
Submersion pressure | ≤0.3 bar |
Climate class | 4K4H (EN/IEC 60721-3-4) |
Shock resistance | 15 g (11 ms), EN/IEC 60068-2-27 |
Vibration resistance | 4 g (10…2000 Hz), EN/IEC 60068-2-6 |
Electromagnetic compatibility (EMC) | Equipment Class B / Industrial Environment (EN/IEC 61326) |
Operating altitude | 2,000 m above sea level |
Mean time to failure (MTTF) | 258 years |
Weight | 0.9 kg |
Materials | |
|---|---|
Materials in contact with the process | PA, aluminium/paint, PES, PUR, brass, nickel, silicone, NBR |
Mechanical | |
|---|---|
Housing design | In-pipe housing (R2) |
Housing diameter | Ø 48 mm |
Overall length | 439 mm |
Mounting flange diameter | Ø 57 mm |
Installation pipe size | From 2" |
Sensor Connectivity | |
|---|---|
Maximum number of connected sensors | 5 |
Maximum number of measured variables | 11 |
Compatible sensor types | Level probes, ultrasonic sensors, radar sensors and similar level measurement sensors |
Alarm Management | |
|---|---|
Alarm functions | Flooding and low water level alerting |
Compliance | |
|---|---|
RoHS Directive | 2011/65/EU |
Battery Regulation | (EU) 2023/1542 |
Radio Equipment Directive (RED) | 2014/53/EU |
Drawing

Downloads
| Hydrolog-HLF4 Datasheet | DownloadHydrolog-HLF4 Datasheet |
|---|---|
| Hydrolog-HLF4 User Manual | DownloadHydrolog-HLF4 User Manual |
| Hydrolog-HLF4 CE Declaration of Conformity | DownloadHydrolog-HLF4 CE Declaration of Conformity |
Related Products

Senseca
DLF4 Data Logger for Autonomous Sensor Data Transmission
Autonomous data logger for up to 7 sensors with analog, RS485 Modbus RTU and digital inputs.
Learn More
Senseca
PH111 Combined pH Electrode for Drinking Water and Clear Media
Combined pH electrode for drinking water and lightly polluted liquids.
Learn More
Senseca
PH101 Combined pH Electrode for Clear and Lightly Polluted Liquids
Combined pH electrode for clear to lightly polluted liquids.
Learn MoreSenseca
UNICON-LF-01/02/03 Conductivity Converter
Conductivity converter for liquid purity and concentration monitoring.
Learn More