Senseca
PH101 Combined pH Electrode for Clear and Lightly Polluted Liquids
Combined pH electrode with a robust PC plastic shaft for clear to lightly polluted liquids.
Measurement range of 0–14 pH
Working temperature of 80 °C and maximum pressure of 5 bar
Gel-filled Ag/AgCl reference system with ceramic diaphragm
Response time under 30 s (pH 4–7)
PG13.5 process connection with 120 mm installation length and 12 mm diameter
Fixed cable with BNC or BNC/Banana plug, S8 or VP industrial plug-in head
Optional Pt1000 temperature compensation for VP and CBT versions
Overview
The Senseca pH101 is a combined pH electrode designed for general-purpose pH measurement in clear to lightly polluted liquids. It covers a measurement range of 0–14 pH and features a robust PC plastic shaft, a gel-filled Ag/AgCl reference system, one ceramic diaphragm and a cylindrical membrane. The electrode has a response time of less than 30 seconds between pH 4 and 7 and requires a minimum media conductivity of 50 µS/cm.
The electrode has a 120 mm installation length, a 12 mm diameter and a PG13.5 process connection, with a working temperature of 80 °C and a maximum pressure of 5 bar. Electrical connection options include a 2 m fixed cable with BNC or BNC/Banana plug, an S8 industrial plug-in head or a VP industrial plug-in head. An optional Pt1000 measuring element is available for temperature compensation in VP and CBT versions.
Typical Applications
General-purpose pH measurement in clear to lightly polluted liquids
pH monitoring in process piping and flow-through systems
pH measurement in open basins
Key Features
Combined potentiometric pH electrode
Measurement range of 0–14 pH
Robust PC plastic shaft with cylindrical membrane
Gel-filled Ag/AgCl reference system with one ceramic diaphragm
Working temperature of 80 °C and maximum pressure of 5 bar
Response time of less than 30 s (pH 4–7)
Minimum media conductivity of 50 µS/cm
120 mm installation length and 12 mm diameter
PG13.5 process connection
Minimum immersion depth of 15 mm
2 m fixed cable with BNC or BNC/Banana plug, S8 or VP industrial plug-in head
Optional Pt1000 measuring element for temperature compensation in VP and CBT versions
Benefits
Wide pH measurement coverage for versatile monitoring requirements
Robust plastic construction supports everyday handling
Fast response between pH 4 and 7 reduces measurement waiting time
Flexible electrical connection options to suit different system configurations
Standard process connection simplifies integration with compatible installation fittings
Optional Pt1000 temperature compensation supports measurement under varying temperatures in VP and CBT versions
Specifications
Measurement | |
|---|---|
Sensor type | Combined pH electrode |
Measuring principle | Potentiometric |
Measurement range | 0–14 pH |
Application scope | Clear to lightly polluted liquids |
Minimum media conductivity | 50 µS/cm |
Response time | < 30 s (pH 4 to 7) |
Operating Conditions | |
|---|---|
Working temperature | 80 °C |
Maximum pressure | 5 bar |
Electrode Construction | |
|---|---|
Shaft material | PC (polycarbonate) |
Reference system | Ag/AgCl |
Reference electrolyte | 3 mol/L KCl gel |
Diaphragm | 1 × ceramic diaphragm |
Membrane shape | Cylindrical |
Mechanical and Installation | |
|---|---|
Diameter | 12 mm |
Installation length | 120 mm |
Minimum immersion depth | 15 mm |
Process connection | PG13.5 |
Installation position | 120° (as specified in the pH101 datasheet) |
Electrical Connection and Temperature Compensation | |
|---|---|
CB version | 2 m fixed cable with BNC plug |
CBT version | 2 m fixed cable with BNC/Banana plug |
S8 version | S8 industrial plug-in head |
VP version | VP industrial plug-in head |
Temperature sensor | Optional Pt1000 (VP and CBT versions only) |
Storage Conditions | |
|---|---|
Storage temperature | −5 to +30 °C |
Storage solution | 3 mol/L KCl solution |
Recommended storage duration | Not longer than 1 year |
Standards and Compliance | |
|---|---|
EU directive | 2011/65/EU (RoHS) |
Harmonised standard | EN IEC 63000:2018 |
Scope of Delivery | |
|---|---|
Included accessory | KCl-filled electrode storage tube with sealing cap |
Downloads
| PH101 Family Datasheet | DownloadPH101 Family Datasheet |
|---|---|
| PH-Redox-Electrodes Family Operating Instructions | DownloadPH-Redox-Electrodes Family Operating Instructions |
| PH101 Family CE Declaration of Conformity | DownloadPH101 Family CE Declaration of Conformity |
Related Products

Senseca
DLF4 Data Logger for Autonomous Sensor Data Transmission
Autonomous data logger for up to 7 sensors with analog, RS485 Modbus RTU and digital inputs.
Learn More
Senseca
HLF4 Autonomous Data Logger for Water Level Monitoring in 2" Pipes
Autonomous data logger for water level monitoring in pipes from 2".
Learn More
Senseca
PH111 Combined pH Electrode for Drinking Water and Clear Media
Combined pH electrode for drinking water and lightly polluted liquids.
Learn MoreSenseca
UNICON-LF-01/02/03 Conductivity Converter
Conductivity converter for liquid purity and concentration monitoring.
Learn More