WETEC

ECD

NA6 Sodium Analyzer


Compact online analyzer for the automatic measurement of sodium in ultrapure water, water/steam cycles, and power plant applications.

  • Measures 10 ppb to 10 ppm sodium ions (Na+Na^+Na+), with a lower detection limit of 0.01 ppb and accuracy of ±\pm±5% of reading or ±\pm±0.1 ppb.

  • Four 4-20 mA outputs and Modbus RTU RS485 communication.

  • Integrated automated sequencer for up to 4 sample streams plus 2 additional streams for standard calibration solutions, supporting manual or automatic calibration.

Quantity
1

Overview

The Model NA6 Sodium Analyzer is a high-precision online system designed for continuous sodium ion ($\text{Na}^+$) determination in ultrapure water production, water/steam cycle applications, and power plant monitoring. Utilizing an ion-selective electrode (ISE) sensitive to sodium ions in solution, the instrument delivers accurate measurements across a selectable full-scale range of 10 ppb to 10 ppm, with a lower detection limit of 0.01 ppb and an accuracy of $\pm 5\%$ of reading or $\pm 0.1\text{ ppb}$ at calibration temperature. Designed for fully automated continuous operation, the analyzer features an integrated multi-channel sequencer capable of switching up to four individual sample streams, alongside two dedicated channels for standard solution tanks to perform seamless manual or automatic 1-point and 2-point calibrations. System integration and data transmission are supported via four 4–20 mA analog outputs and digital Modbus RTU RS485 communication

Typical Applications

  • Ultrapure water production/monitoring

  • Water/steam cycle

  • Power plants

Key Features

  • Automated 4-Channel Sequencer: Switches up to 4 sample streams using a programmable multi-position valve, featuring dedicated fast-loop reservoirs on each line to minimize switching times and eliminate cross-contamination.

  • Measurement principle The instrument takes measurements with an Ion Selective Electrode (ISE) sensitive to sodium ions in solution. The response of the electrode is proportional to the sodium concentration in the sample on a logarithmic scale

  • Wide measuring range, low detection limit The ECDA‐NA analyzer has good performance even in the low range 0 ‐ 10 ppb. Upper limit of detection can be up to 10 ppm. Upper ranges available on request

Benefits

  • Fully automated, one or two‐point calibration The automatic calibration of the electrochemical sensors significantly reduces downtime and operator intervention, ensuring that the most accurate results are obtained. User can determine the frequency of these operations

  • Color touchscreen The analyzer is equipped with a graphic touchscreen interface showing measured values and status information. Easy access to menus and functions. Integrated datalogger with USB download.

Specifications

MEASUREMENT

 

Measured parameter

Sodium ion, Na⁺ (ppb, ppm)

Measuring principle

Potentiometric detection with glass electrode and reference (or combined electrode)

Measuring range

Selectable full scale 10 ppb ‐ 10 ppm

Lower detection limit

0.01 ppb

Accuracy

± 5% of the reading or ± 0.1 ppb at calibration temperature

Analysis frequency

Continuous operation

Calibration

Manual or automatic, 1‐point or 2‐point calibration

 

 

SAMPLE & STREAMS

 

Sample

Pressure: Atmospheric
Temperature: 5 ‐ 50 °C (41 ‐ 122 °F)
Flow Rate: 80 to 500 ml/min
Connection: 6 mm (¼‐in.)

Drain

Pressure‐free, atmospheric drain
Connection: 12 mm (½‐in.)

N° of streams

Up to 4 sample streams, 2 additional streams for standard solution(s)

 

 

ELECTRICAL

 

Power supply

Voltage: 100 ‐ 240 VAC 50/60 Hz standard
Power consumption: max. 80 VA

Outputs

4 x 4‐20 mA outputs for measured data
Modbus RTU RS485

Alarms

4 SPDT programmable potential free relays

 

 

PHYSICAL & ENVIRONMENTAL

 

Dimensions (H x W x D)

604 x 900 x 242 mm (23.6 x 35.4 x 9.4 in)

Weight

Approx. 30 kg (66 lbs)

Operative conditions

Temperature: 5 ‐ 50 °C (41 ‐ 113 °F)
Humidity: 10 to 90% RH (indoor use only)

Installation

Wall mount (standard) or panel mount (options)

Protection grade

IP54

Maintenance frequency

Refill buffer solution (monthly)
Electrode replacement (depending on samples)
Pinch valve tubing replacement every 6 month

Drawing

Downloads

ECDA_NA6_Sodium Analyzer Datasheet pdf (EN) DownloadECDA_NA6_Sodium Analyzer Datasheet pdf (EN)